Remove the side dust-proof clips and blow compressed air through the condenser coils to clear accumulated shop dust.
Note: The indicates high water (allow room for expansion), and the Red Zone indicates critically low water. 4. Temperature Controller Programming
The CWFL-6000 is not a standard aquarium pump. It is a precision refrigeration unit with two independent water circulation systems:
Use low-pressure compressed air to clean the internal condenser fins from the inside out. Every 3 to 6 Months
T1 is set too low relative to room dew point. The manual contains a psychrometric chart. Raise T1 to 25°C if ambient humidity exceeds 70%.
Add a specialized laser-approved antifreeze (like Teyu’s official antifreeze or a localized glycol mix specified for lasers) strictly following recommended dilution ratios. Drain the mixture completely once spring arrives. 7. Storage and Transportation
The CWFL-6000 utilizes an intelligent T-507 dual-channel temperature controller. It features two primary operating modes: and Constant Mode . Mode Definitions
Routine maintenance extends the life of your chiller significantly.
The layout features clear entry and exit mechanisms across the chassis to simplify deployment:
The chiller maintains a fixed user-defined temperature regardless of ambient shifts. This mode is preferred in highly climate-controlled facilities. Changing Parameters (e.g., Switching to Constant Mode) To modify settings, you must unlock the controller panel: